59 • Schlage • Schlage Utility Soware User's Guide
Error CodesTroubleshooting
Error Codes
No. Error Solution
E510 The ADA Delay value should be in range
0- 255
The ADA Delay entered was greater than 255. Enter a
value less than 255 and try again.
E600 Please select the firmware file No firmware file was selected before the OK menu
item was tapped when attempting to update the lock’s
firmware. Select a firmware file and try again.
E601 Updating firmware failed The HHD was disconnected from the lock before the
firmware update was complete. The HHD must remain
connected to the lock until the firmware update is
complete.
No valid programming credential was presented to
the lock. A valid programming credential must be
presented before the firmware update can be done.
SUS may need to be updated in order to perform
firmware updates to this device. Please check
www.schlage.com/support for the latest version.
E602 No files to select The HHD does not have any files to select from or they
were put in the incorrect folder.
E603 File integrity check failed While updating Firmware or Programming a lock,
the SUS soware detected that the file being used is
corrupted. Download/Create the file again and upload
it into the HHD.
E604 Cannot open file
E605 Cannot read file
E606 Invalid file
E607 Please select the lock class file While attempting to change a lock class, inside the
Firmware Package Screen – no selections were made.
Select a lock class and try again.
E700 Please select the door While attempting to program a lock, no door was
selected. Select a door and try again.
E701 Programming lock failed The HHD was disconnected from the lock before
the lock setup was complete. The HHD must remain
connected to the lock until the lock setup is complete.
No valid programming credential was presented to
the lock. A valid programming credential must be
presented before the lock can be set up.
E702 The door file is invalid due to incorrect
data present; for example, blank lines.
This can occur for multiple reasons,
including manually editing the door file.
Use SMS to regenerate the door file & load the new
door file into the SUS. Then retry programming.
E703 Door file contains invalid data for the
AD200 lock model. Verify the correct
lock and door files are selected or
regenerate the door file and try again.
Click OK to continue.
The Doorfile used contains IButton Data. This data is
not valid for an AD200 Lock. Ensure the correct door/
doorfile is selected or regenerate the doorfile.
E704 The selected Door file contains format
errors. Click OK to Continue or Cancel
to exit and try again using a new door
file.
The doorfile contains errors that may interfere with
normal operation. Programming is allowed to proceed
if OK is selected. It is recommended that the doorfile
be generated again by the access soware in order to
ensure the expected function of the lock.