36 • Schlage • Schlage Utility Soware User's Guide
Controller PropertiesAD-Series Locks and Controllers
PIM400 -TD2, -485, -VBB (PIM PROPERTIES)
VIEW Tab
Property Description
General Properties
Model Model number of the device connected to the HHD.
Source ID Unique identifier for the PIM400.
PIM
RS485 Partner ID Identifies the participating OEM soware partner.
Firmware Version Version of the current firmware file. Automatically updated when a new firmware version is
loaded.
Bootloader version Version of the current bootloader. Allows new firmware to be loaded.
Serial No. Serial number that uniquely identifies the device.
Manufacture Date Date the device was manufactured.
Days since Installed Used for warranty purposes; marks the beginning of the lock’s functional life.
Hardware Version Current version of the printed circuit main board.
Communication
Firmware Version Version of the communication module firmware.
EDIT Tab
Property Description Default
Unique ID Set the Unique Identification number of the PIM400. Range: 0 to 65534.
Freq Channel Radio Frequency Channel used for communication with wireless devices. One of
ten RF channels can be set.
1
RS-485 Address PIM400 -485 and PIM400-VBB ONLY. Set the RS-485 network address of the
PIM400/401. Address range 0-254
0
Low Door PIM400 -485, -VBB ONLY. Set the Low address for the range of door addresses
available for linking. Range: 0 to 255
0
High Door PIM400 -485, -VBB ONLY. Set the High address for the range of door addresses
available for linking. Range: 0 to 255
15
Channel Switching Dynamic Channel Switching is used to improve immunity to RF channel
interference. One of three RF channel groups can be set.
Disabled
Wakeup When enabled, this feature causes wireless devices linked to the PIM400/401 to
respond within seconds to a centralized command from the access control panel.
When disabled, the wireless devices will respond only during their heartbeat, which
could result in a delay. Range 0 to 10 seconds. 0= disabled
Disabled
Output Type (PIM400-
TD2 only)
Magnetic, Wiegand or Automatic. Outputs the Credential Card and Keypad data in
either Magnetic or Wiegand format.
When Automatic is selected, the PIM400-TD2 will detect the Credential Card and
Keypad data format and then send the received data in its original data format.
Automatic