42 • Schlage • Schlage Utility Soware User's Guide
Controller PropertiesAD-Series Locks and Controllers
WRI400
VIEW Tab
Property Description
General Properties
Model Model number of the device connected to the HHD.
Main Lock
RS485 Partner ID Identifies the participating OEM soware partner.
Serial Number Serial number that uniquely identifies the WRI400.
Manufacture Date Date the WRI400 was manufactured.
Days Since Installed Used for warranty purposes; marks the beginning of the WRI400 functional life.
Firmware Version Version of the current firmware file. Automatically updated when new firmware file is loaded.
Hardware Version Current version of the printed circuit main board.
Bootloader Version Version of the current bootloader. Allows new firmware to be loaded.
Communication
Serial Number Serial number that uniquely identifies the communication module.
Firmware Version Version of the communication module firmware.
EDIT Tab
Property Description Default
Heartbeat The heartbeat is a brief communication from the WRI400 to the PIM400.
It allows the WRI400 to check for messages. Range: 1 s. – 65535 s.
The value indicates the time between the heartbeats. Set to a shorter time (lower
number) for more frequent communication. Set to a longer time (higher number) for
less frequent communication.
A smaller value will decrease battery life. A larger value will increase battery life.
10 minutes
Comm Loss Fail Mode WRI400 state set when the RF communication with the linked PIM400 fails. States:
As-Is, Secure/Lock, Unsecure/Unlock
As-Is
Allow Extended
Unlocks
Extended unlock permits the WRI400 to stay in an indefinite unlock state (available
only in a PIM400-TD2).
Enabling the Extended Unlock feature is required to implement a scheduled unlock
period from an Access Control Panel.
Enabled
Report RTX for Host
to unlock
Determines how the WRI400 handles a request to exit.
If disabled, the WRI400 will only report that a request to exit has occurred. Disable
if the WRI400 does not need to be electronically unlocked to provide egress (if
equipped with a crash bar) but the access control panel needs to be notified so that a
forced door does not occur.
If enabled, the WRI400 will report that a request to exit has occurred, and also will
query the PIM400 to determine if it should be electronically unlocked. Use this mode
if the WRI400 needs to be electronically unlocked in order to provide egress.
Enabled
Relatch Aer Amount of time before the WRI400 re-locks aer being unlocked by a user presenting
a valid credential.
The value set in the HHD is only used if the Access Control Panel (ACP) responds
with a “Momentary Unlock” command. When the Access Control Panel sends the
number of seconds to unlock the WRI400 then the relatch aer value set in the HHD
is ignored.
3 seconds
Relatch Aer: Timer/
Door Status
Timer Only: Locks the WRI400 when timer expires regardless of its status or position.
On Door Open or Timer: Locks WRI400 when it opens or Timer expires.
On Door Close or Timer: Locks WRI400 when it closes or Timer expires.
Timer Only