Asus DS300f Especificaciones Pagina 221

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 262
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 220
DS300f G2 Series User Manual
215
rebuIlDInG a DISk array
Whenyourebuildadiskarray,youareactuallyrebuildingthedataononephysicaldrive.
• Whenaphysicaldriveinadiskarrayfailsandasparedriveofadequatecapacityisavailable,thediskarray
beginstorebuildautomaticallyusingthesparedrive.
• Ifthereisnosparedriveofadequatecapacity,buttheAutoRebuildfunctionisENABLED,thediskarray
beginstorebuildautomaticallyassoonasyouremovethefailedphysicaldriveandinstallanuncongured
physicaldriveinthesameslot.See“MakingRebuildSettings”
• IfthereisnosparedriveofadequatecapacityandtheAutoRebuildfunctionisDISABLED,youmustreplace
thefaileddrivewithanunconguredphysicaldrive,thenperformaManualRebuild.See“RebuildingaDisk
Array”
Important
Ifyourreplacementdiskdrivewasformerlypartofadifferentdiskarrayorlogicaldrive,
youmustclearthecongurationdataonthereplacementdrivebeforeyouuseit.See
“Clearing a Stale or a PFA Condition”
•
IncomPlete array
A moreserious,butfarless common problem is an Incomplete Array. An incomplete array results from a
physical drive that fails or becomes missing during:
• RAID level migration
• Disk array transport
MigrAtion
Normally,ifaphysicaldriveorthecontrollerfailsduringmigration,thediskarraygoescritical,andyoucan
rebuildit.
trAnsPort
Transport is the action of moving the physical drives of a disk array:
• To different slots in the same enclosure
• From one enclosure to another
Ifaphysicaldrivefailsduringatransport,oryoudonotmoveallofthephysicaldrivestotheirnewlocations,
ASUS Storage Management displays an incomplete array. When ASUS Storage Management discovers an
incompletearray,itdisplaysadialogboxaskingyouto:
• Click the OKbuttontoaccepttheincompletearray.
• Click the Cancelbuttontorejecttheincompletearray.
AccePting An incoMPlete ArrAy
Beforeyouaccepttheincompletearray,besureallofthephysicaldrivesarepresentandthattheirdrivecarriers
areproperlyinstalledintotheenclosure.See“InstallingPhysicalDrives”
If you choose to accept the incomplete array:
1. ClickOKintheincompletearraydialogbox.
2. Checktheoperationalstatusofthelogicaldrivesinthearray.
• IfthelogicaldrivesareCritical,proceedwitharebuild.
• IfthelogicaldrivesareOfine,contactTechnicalSupport.
3.
Restoreyourdatafromabackupsource.
If you choose NOT to accept the incomplete array:
1. Click Cancelintheincompletearraydialogbox.
2. Do one of the following:
•
Deletethearray.Thisactiondeletesalllogicaldrivesonthearray.
• Replacethemissingphysicaldrive.
Vista de pagina 220
1 2 ... 216 217 218 219 220 221 222 223 224 225 226 ... 261 262

Comentarios a estos manuales

Sin comentarios