A-8 Using the CFGGEN IR Configuration Utility
Version 1.1 Copyright © 2006, 2007 by LSI Logic Corporation. All rights reserved.
Program Return Value –
0x00 SUCCESS: command completed successfully.
0x01 FAILURE: bad command line arguments or operational failure.
Sample Output –
The following example shows a sample output of the CREATE command
when used to create an IM configuration.
Read configuration has been initiated for controller 0
------------------------------------------------------------------------
Controller information
------------------------------------------------------------------------
Controller type : LSI1064/1068
BIOS version : 6.05.05.00
Firmware version : 0.07.01.00
SCSI channel description : 1 Serial Attached SCSI
Initiator IDs (SCSI ID) : 63
Maximum physical devices : 62
Concurrent commands supported : 511
Slot : 1
Bus : 2
Device : 2
Function : 0
------------------------------------------------------------------------
IR Volume information
------------------------------------------------------------------------
IR volume 1
Status of volume : Okay (OKY)
RAID level : 1
Size (in MB) : 34332
Physical hard disks (SCSI ID) : 10 7
------------------------------------------------------------------------
Enclosure information
------------------------------------------------------------------------
Enclosure # : 1
Enlcosure WWN : 12345678:ABCDABCD
Start Slot : 1
Num Slots : 4
Start SCSI ID : 0
------------------------------------------------------------------------
Physical device information
------------------------------------------------------------------------
Initiator at SCSI ID 63
Target on SCSI ID 7
Enclosure # : 1
Slot # : 1
Device is a Hard disk
SCSI ID : 7
State : Online (ONL)