Asus ASMB3-SOL PLUS Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware De La Computadora Asus ASMB3-SOL PLUS. Asus ASMB3-SOL PLUS User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 70
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
ASMB3-SOL PLUS
Server Management Board
Vista de pagina 0
1 2 3 4 5 6 ... 69 70

Indice de contenidos

Pagina 1 - ASMB3-SOL PLUS

ASMB3-SOL PLUSServer Management Board

Pagina 3 - Contents

1Chapter 1: Product introductionThis chapter describes the server management board features and the new technologies it supports.

Pagina 4

1-2 Chapter 1: Product introduction1.1 Welcome!Thank you for buying an ASUS® ASMB3-SOL PLUS server management board! The ASUS ASMB3-SOL PLUS is an In

Pagina 5

ASUS ASMB3-SOL PLUS 1-31.3 Board layoutThe ASUS ASMB3-SOL PLUS comes in a BMC package. The illustration below shows the major components of the serve

Pagina 6 - Safety information

1-4 Chapter 1: Product introduction1.5 Network and smart phone setupThe ASMB3-SOL PLUS server management board installed on the remote server connect

Pagina 7 - About this guide

2Chapter 2: InstallationThis chapter provides instructions on how to install the board to the server system and install the utilities that the board

Pagina 8 - Typography

2-2 Chapter 2: Installation2.2 Hardware installationThe illustrations shown in this section are for reference only and may not be exactly the same as

Pagina 9

ASUS ASMB3-SOL PLUS 2-34. Press the board rmly until the BMC socket retaining clips snap back and secure the board in place. When installed, the bo

Pagina 10

2-4 Chapter 2: InstallationTo uninstall the board:1. Simultaneously push the BMC socket retaining clips outward until the board tilts up.2. Carefull

Pagina 11 - Chapter 1: Product

ASUS ASMB3-SOL PLUS 2-52.3 Firmware update and IP congurationYou need to update the IPMI and ASMB3-SOL PLUS rmware before you start using the ASMB3

Pagina 12 - 1.2 Package contents

iiE3890Second Edition V2 May 2008Copyright © 2008 ASUSTeK COMPUTER INC. All Rights Reserved.No part of this manual, including the products and softwar

Pagina 13 - 1.4 System requirements

2-6 Chapter 2: Installation3. A screen appears, showing the current (if any) rmware version, and the new rmware version. The screen also displays a

Pagina 14 - Direct LAN connection

ASUS ASMB3-SOL PLUS 2-72.3.3 Congure BMC IP source static IP1. Repeat the step 1-4 in the previous sub-section.2. On reboot, the main menu appears

Pagina 15 - Chapter 2: Installation

2-8 Chapter 2: Installation2.3.4 Congure BMC IP source DHCP1. Repeat the step 1-4 in the previous sub-section.2. On reboot, the main menu appears.

Pagina 16 - 2.2 Hardware installation

ASUS ASMB3-SOL PLUS 2-92.4 BIOS congurationYou need to adjust the settings in the BIOS setup of the remote server for correct conguration and conne

Pagina 17 - ASUS ASMB3-SOL PLUS 2-3

2-10 Chapter 2: InstallationYou must congure the network settings of both the remote server and the local/central server to establish communication f

Pagina 18 - 2-4 Chapter 2: Installation

ASUS ASMB3-SOL PLUS 2-11Boot Option Uses [System]Set this item to [System] if you want the BIOS to control the boot option. Set to [BMC] if you want t

Pagina 19 - 2.3.1 LAN rmware update

2-12 Chapter 2: InstallationLAN SettingAllows you to set the BMC LAN Parameter settings. Select Screen Select Item+- Change OptionF1 General HelpF1

Pagina 20 - 2-6 Chapter 2: Installation

ASUS ASMB3-SOL PLUS 2-134. Press <Esc>, then select IPMI Conguration sub-menu from the Server menu.5. Use this sub-menu to adjust the remote

Pagina 21 - ASUS ASMB3-SOL PLUS 2-7

2-14 Chapter 2: InstallationRunning the BIOS IPMI congurationTo congure the IPMI in the BIOS:1. Restart the remote server, then press <Del> d

Pagina 22 - 2-8 Chapter 2: Installation

ASUS ASMB3-SOL PLUS 2-15IPMI Specification VersionThis item shows the auto-detected IPMI specication version.BMC Firmware VersionThis item shows the

Pagina 23 - 2.4 BIOS conguration

iiiContentsContents ... iiiNotices ...

Pagina 24 - IPMI Conguration

2-16 Chapter 2: InstallationScroll down to display more items.System Event Log Press <Enter> to open the System Event Log, which allows you to v

Pagina 25 - ASUS ASMB3-SOL PLUS 2-11

ASUS ASMB3-SOL PLUS 2-17System Event Log (list mode) Press <Enter> to open the System Event Log in list mode. F1 Help ↑↓ Select Item

Pagina 26 - LAN Setting

2-18 Chapter 2: Installation Refer to the table on the next page for a description of the help menu options.2.5 Running the ASMC2 utilityThe ASUS Se

Pagina 27 - 2.4.2 Phoenix BIOS setup

ASUS ASMB3-SOL PLUS 2-19ASMC2 Help Menu optionsOptions Description-ash -load lename Update the ASMB3-SOL PLUS rmware-sdr -save lename Save the SDR

Pagina 28

2-20 Chapter 2: Installation2.5.1 Conguring the LAN controllerBefore you can establish connection to the ASMB3-SOL PLUS board, you must congure the

Pagina 29

ASUS ASMB3-SOL PLUS 2-217. Congure your (a) subnet mask and (b) gateway address if needed.(a) Type asmc2 -bmc_mask xxx.xxx.xxx.xxx (your subnet mas

Pagina 30 - Date Separator [/]

2-22 Chapter 2: Installation2.5.2 Using ASWM to update the ASMB3-SOL PLUS rmwareYou can use the ASUS System Web-based Management (ASWM) application

Pagina 31 - IP Address

ASUS ASMB3-SOL PLUS 2-232.6 Software installationYou can monitor, control, or manage the remote server from the local/central server using the ASUS

Pagina 32 - 2-18 Chapter 2: Installation

2-24 Chapter 2: Installation3. Follow the installation wizard instructions to install the utility.2.6.2 Launching ARCTo launch the ARC utility, clic

Pagina 33 - ASMC2 Help Menu options

3Chapter 3: Software supportThis chapter tells you how to use the software applications that the server management board supports.

Pagina 34 - OS to check

ivContents3.1.5 Displaying system event logs ...3-113.1.6 Using Remote Console ...

Pagina 35 - ASUS ASMB3-SOL PLUS 2-21

3-2 Chapter 3: Software support3.1 ASUS Remote Console (ARC)The ASUS Remote Console (ARC) is a web-based utility that allows you to monitor the remot

Pagina 36 - 2-22 Chapter 2: Installation

ASUS ASMB3-SOL PLUS 3-33.1.1 ARC sectionsMenu barThe Menu bar contains all the commands for the ARC application. Click on a menu to display a list of

Pagina 37 - 2.6 Software installation

3-4 Chapter 3: Software supportSome remote server information (such as the SDR) contains several sensor groups such as Temperature, Voltage, and Fan.

Pagina 38 - 2.6.2 Launching ARC

ASUS ASMB3-SOL PLUS 3-5Event windowThe Event window displays the Platform Event Trap (PET) received by the ARC. The PET information includes the event

Pagina 39 - Chapter 3: Software

3-6 Chapter 3: Software support3.1.2 Connecting to the remote serverTo connect to the remote server:1. From the menu bar, click Server, then select

Pagina 40

ASUS ASMB3-SOL PLUS 3-7 The navigation window displays the remote server. The available remote server information are displayed on the Detail/SEL win

Pagina 41 - 3.1.1 ARC sections

3-8 Chapter 3: Software support3.1.3 Retrieving sensor informationThe Sensor Data Record (SDR) provides remote server system information through avai

Pagina 42 - Sensor groups

ASUS ASMB3-SOL PLUS 3-93. Click More. A sensor window appears displaying additional information on the sensor. The Information tab displays basic se

Pagina 43 - Detail/SEL window

3-10 Chapter 3: Software support3.1.4 Displaying FRU informationThe Field Replaceable Unit (FRU) information provides the manufacturer, product name,

Pagina 44

ASUS ASMB3-SOL PLUS 3-113.1.5 Displaying system event logsThe System Event Log (SEL) is a non-volatile storage area where all remote server system ev

Pagina 45

vNoticesFederal Communications Commission StatementThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two condi

Pagina 46

3-12 Chapter 3: Software support3.1.6 Using Remote ConsoleThe Remote Console feature lets you see the remote server screen (text only) and is useful

Pagina 47 - ASUS ASMB3-SOL PLUS 3-9

ASUS ASMB3-SOL PLUS 3-133.1.7 Displaying all remote server sensorsTo display all remote server sensors in graphical format:1. From the navigation wi

Pagina 48

3-14 Chapter 3: Software support3.1.8 Adjusting the monitoring settingsThe ARC application allows you to adjust the remote server monitoring settings

Pagina 49 - ASUS ASMB3-SOL PLUS 3-11

ASUS ASMB3-SOL PLUS 3-15Enabling the Short Message Service (SMS) featureThe Short Message Service or SMS feature allows you to receive Platform Event

Pagina 50 - 3.1.6 Using Remote Console

3-16 Chapter 3: Software support3.1.9 Controlling the remote server powerARC allows you to power up, power down, or reset the remote server using the

Pagina 51 - ASUS ASMB3-SOL PLUS 3-13

ASUS ASMB3-SOL PLUS 3-173.1.10 Viewing PET informationThe Platform Event Trap or PET is an SNMP trap used for system management alerts. When the ARC

Pagina 52

3-18 Chapter 3: Software support4. Double-click Management and Monitoring Tools.5. Select Simple Network Management Protocol (SNMP).6. Click OK.

Pagina 53

ASUS ASMB3-SOL PLUS 3-19Important notice for Windows® XP (Service Pack 2) usersIf the local server system is behind a rewall, you must create a UDP p

Pagina 54 - Power Down

3-20 Chapter 3: Software support3.2 ASUS Host Management Controller SetupThe ASUS Host Management Controller Setup utility provides precise congurat

Pagina 55 - PET information

ASUS ASMB3-SOL PLUS 3-213.2.2 Command eldsThe utility menu bar has ve commands: Initial, View, Set, Monitor and Help. You can select a command usin

Pagina 56

viSafety informationElectrical safety• To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the

Pagina 57 - XP (Service Pack 2) users

3-22 Chapter 3: Software supportTo view the System Data Record (SDR):1. Select BMC SDR from the View command option, then press <Enter>. A comp

Pagina 58 - Controller Setup utility

ASUS ASMB3-SOL PLUS 3-23To view the BMC information:1. Select BMC Info from the View command option, then press <Enter>. A list of BMC informat

Pagina 59 - 3.2.3 Initial

3-24 Chapter 3: Software support3.2.5 SetThe Set command controls the host interface type and the correct BMC time.You can select from the following

Pagina 60

ASUS ASMB3-SOL PLUS 3-253.2.6 MonitorThe Monitor command displays real-time data on the remote server system and CPU temperatures, voltages, and fan

Pagina 61 - To view the BMC information:

3-26 Chapter 3: Software support3.2.7 HelpThe Help command displays the available utility options, utility version, and copyright information.

Pagina 62 - 3.2.5 Set

AAppendix: Reference informationThe Appendix shows the location of the LAN port for server management and BMC socket on several motherboards. This se

Pagina 63 - 3.2.6 Monitor

A-2 Appendix: Reference informationA.1 LAN port for server managementThe ASUS server motherboards that support the ASMB3-SOL PLUS comes with two LAN

Pagina 64 - 3.2.7 Help

ASUS ASMB3-SOL PLUS A-3A.2 BMC socketThe ASUS server motherboards that support the ASMB-LE comes with a Baseboard Management Controller (BMC) socket.

Pagina 65 - Appendix: Reference

A-4 Appendix: Reference informationA.3 Converting decimal to hexadecimal1. Divide the decimal number by 16 and you will get a quotient and a remaind

Pagina 66 - KFN4-DRE motherboard

ASUS ASMB3-SOL PLUS A-5A.4 TroubleshootingProblem SolutionThe local/central server cannot connect to the ASMB3-SOL PLUS board.1. Check if the LAN ca

Pagina 67 - A.2 BMC socket

viiAbout this guideThis user guide contains the information you need when installing and conguring the server management board.How this guide is orga

Pagina 68

A-6 Appendix: Reference informationProblem SolutionSerial Over LAN (SOL) 1. Check the BIOS remote console setting. See section 2.4 for details.2. Ch

Pagina 69 - A.4 Troubleshooting

viiiTypographyBold text Indicates a menu or an item to select.Italics Used to emphasize a word or a phrase.<Key> Keys enclosed in the less

Pagina 70 - Troubleshooting

ixASMB3-SOL PLUS specications summary* Specications are subject to change without notice.IPMI features IPMI 2.0-compliant and supports: - Auto m

Comentarios a estos manuales

Sin comentarios