3-3ASUS ESC4000 G2 Series
3.1.2 Attaching the rack rails
To attach the rack rails
1. Place the two front rail rack joints into the rear rail rack slots, as shown in the
following gure.
2. Attach the front and rear rail racks with eight screws and nuts, as shown in
the following gure. Do not secure the screws too tight so that you can still
adjust the length of the rack rails to meet the depth of the server rack.
Front rail rackRear rail rack
Frontrailrackjoints
Rear rail rack slots
7. Secure the front end of the rail with
two rack screws, as shown in the
right gure.
8. Secure the rear end of the rail with
two rack screws, as shown in the
right gure.
9. Fasten the eight screw you secure
in step 2, as shown in the right
gure.
10. Repeat steps 6 to 9 to assemble
and attach the rack rail on the other
side.
3. Select two units of space (2U) on the rack where you want to install the
barebone server.
4. Measure the depth of the rack to determine the length of the rack rails.
5. Adjust the rack rail to ensure that it ts the rack.
6. Position the rack rail to the 2U space on the rack. Ensure that the front end of
the rack rail goes to the front of the rack space.
7
9
8
7
9
8