Asus ASMB4-IKVM Especificaciones

Busca en linea o descarga Especificaciones para Servidores Asus ASMB4-IKVM. Asus ASMB4-IKVM Specifications Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 84
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
ASMB4-iKVM/
ASMB4-SOL PLUS
Server Management Board
Vista de pagina 0
1 2 3 4 5 6 ... 83 84

Indice de contenidos

Pagina 1 - ASMB4-SOL PLUS

ASMB4-iKVM/ASMB4-SOL PLUSServer Management Board

Pagina 2 - March 2011

xTypographyBold text Indicates a menu or an item to select.Italics Used to emphasize a word or a phrase.<Key> Keys enclosed in the less-th

Pagina 3 - Contents

xiASMB4-iKVM/ASMB4-SOL PLUS specications summaryChipset Aspeed 2050Internal RAM 56 Mb for system 8 Mb for videoInternal ROM 16 MbTimers 32-bit Watchd

Pagina 5

1Chapter 1: Product introductionThis chapter describes the server management board features and the new technologies it supports.

Pagina 6

1-2 Chapter 1: Product introduction1.1 Welcome!Thank you for buying an ASUS® ASMB4-iKVM/ASMB4-SOL PLUS server management board!The ASUS ASMB4-iKVM/AS

Pagina 7

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 1-31.3 Features1. IPMI 2.0• System interface (KCS)• LAN interface (support RMCP+)• System Event Log (SEL)• Sensor

Pagina 8 - Safety information

1-4 Chapter 1: Product introduction1.4 System requirementsBefore you install the ASMB4-iKVM/ASMB4-SOL PLUS board, check if the remote server system m

Pagina 9 - About this guide

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 1-51.5 Network setupThe ASMB4-iKVM/ASMB4-SOL PLUS server management board installed on the remote server connects to a

Pagina 10 - Typography

1-6 Chapter 1: Product introduction

Pagina 11 - ASMB4-iKVM/ASMB4-SOL PLUS

2Chapter 2: InstallationThis chapter provides instructions on how to install the board to the server system and install the utilities that the board

Pagina 12

iiE6568Second Edition V2 March 2011Copyright © 2011 ASUSTeK COMPUTER INC. All Rights Reserved.No part of this manual, including the products and softw

Pagina 13 - Chapter 1: Product

2-2 Chapter 2: Installation2.2 Hardware installationTo install the server management board:1. Remove the remote server system cover, and then locate

Pagina 14 - 1.2 Package contents

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-34. When installed, the board appears as shown.5. Reinstall the remote server system cover, then connect the power

Pagina 15 - 1.3 Features

2-4 Chapter 2: Installation2.3 Firmware update and IP congurationYou need to update the ASMB4-iKVM/ASMB4-SOL PLUS rmware and congure IP source bef

Pagina 16 - 1.4 System requirements

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-57. When the update process is completed, the following screen appears.When the update process is completed, the fol

Pagina 17 - 1.5 Network setup

2-6 Chapter 2: Installation2.3.2 Congure BMC IP source static IP1. Repeat the step 1-4 in the previous sub-section.2. On reboot, the main menu app

Pagina 18

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-72.3.3 Congure BMC IP source DHCP1. Repeat the step 1-4 in the previous sub-section.2. On reboot, the main menu a

Pagina 19 - Chapter 2: Installation

2-8 Chapter 2: Installation2.4 BIOS congurationYou need to adjust the settings in the BIOS setup of the remote server for correct conguration and c

Pagina 20 - 2.1 Before you proceed

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-9Set LAN1/LAN3 ConfigurationAllows you to set the BMC LAN Parameter settings.IP Address SourceAllows you to select th

Pagina 21

2-10 Chapter 2: InstallationIt is necessary to install ASWM (ASUS System Web-based Management) for using this function. Select Screen Select Item+-

Pagina 22 - 2.3.1 Firmware update

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-112.5 Running the ASMC4 utilityThe ASMC4 utility allows you to update the ASMB4-iKVM/ASMB4-SOL PLUS rmware, congur

Pagina 23

iiiContentsNotices ... viSafety information ...

Pagina 24 - Press any key to continue

2-12 Chapter 2: InstallationASMC4 Help Menu optionsOptions Description-kcs[smic/bt/pci_smic] NetFn command data...Send IPMI command-bmc_ip_source sou

Pagina 25 - New BMC IP Source : DHCP

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-132.5.1 Conguring the LAN controllerBefore you can establish connection to the ASMB4-iKVM/ASMB4-SOL PLUS board, you

Pagina 26 - 2.4 BIOS conguration

2-14 Chapter 2: Installation2.5.2 Conguring the user name and passwordYou may change your user name and password from the ASMC4 utility.To change th

Pagina 27 - Set LAN1/LAN3 Configuration

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 2-152.6 Software installationYou can monitor, control, or manage the remote server from the local/central server using

Pagina 28 - Clear BMC System Event Log

2-16 Chapter 2: Installation3. Follow the installation wizard instructions to install the utility.2.6.2 Launching ARCTo launch the ARC utility, clic

Pagina 29

3Chapter 3: ASUS Remote ConsoleThis chapter tells you how to use the ASUS Remote Console (ARC) that the server management board supports.

Pagina 30 - ASMC4 Help Menu options

3-2 Chapter 3: ASUS Remote Console3.1 ASUS Remote Console (ARC)The ASUS Remote Console (ARC) is a web-based utility, designed for ASMB4-SOL PLUS, tha

Pagina 31 - OS to check

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-33.1.1 ARC sectionsMenu barThe Menu bar contains all the commands for the ARC application. Click on a menu to displa

Pagina 32 - 2-14 Chapter 2: Installation

3-4 Chapter 3: ASUS Remote ConsoleSome remote server information (such as the SDR) contains several sensor groups such as Temperature, Voltage, and Fa

Pagina 33 - 2.6 Software installation

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-5Event windowThe Event window displays the Platform Event Trap (PET) received by the ARC. The PET information include

Pagina 34 - 2.6.2 Launching ARC

ivContents3.1.8 Adjusting the monitoring settings ... 3-143.1.9 Controlling the remote server power ...

Pagina 35 - Remote Console

3-6 Chapter 3: ASUS Remote Console3.1.2 Connecting to the remote serverTo connect to the remote server:1. From the menu bar, click Server, then sele

Pagina 36

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-7 The navigation window displays the remote server. The available remote server information are displayed on the Det

Pagina 37 - 3.1.1 ARC sections

3-8 Chapter 3: ASUS Remote Console3.1.3 Retrieving sensor informationThe Sensor Data Record (SDR) provides remote server system information through a

Pagina 38 - Sensor groups

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-93. Click More. A sensor window appears displaying additional information on the sensor. The Information tab displa

Pagina 39 - Detail/SEL window

3-10 Chapter 3: ASUS Remote Console3.1.4 Displaying FRU informationThe Field Replaceable Unit (FRU) information provides the manufacturer, product na

Pagina 40

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-113.1.5 Displaying system event logsThe System Event Log (SEL) is a non-volatile storage area where all remote serve

Pagina 41

3-12 Chapter 3: ASUS Remote Console3.1.6 Using Remote ConsoleThe Remote Console feature lets you see the remote server screen (text only) and is usef

Pagina 42

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-133.1.7 Displaying all remote server sensorsTo display all remote server sensors in graphical format:1. From the na

Pagina 43

3-14 Chapter 3: ASUS Remote Console3.1.8 Adjusting the monitoring settingsThe ARC application allows you to adjust the remote server monitoring setti

Pagina 44

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-15Enabling the Short Message Service (SMS) featureThe Short Message Service or SMS feature allows you to receive Plat

Pagina 45

vContents4.5.4 Chassis Identify Command ... 4-134.6 Maintenance ...

Pagina 46 - 3.1.6 Using Remote Console

3-16 Chapter 3: ASUS Remote Console3.1.9 Controlling the remote server powerARC allows you to power up, power down, or reset the remote server using

Pagina 47

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-173.1.10 Viewing PET informationThe Platform Event Trap or PET is an SNMP trap used for system management alerts. Wh

Pagina 48

3-18 Chapter 3: ASUS Remote Console4. Double-click Management and Monitoring Tools.5. Select Simple Network Management Protocol (SNMP).6. Click O

Pagina 49

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-19Important notice for Windows® XP (Service Pack 2) usersIf the local server system is behind a rewall, you must cre

Pagina 50 - Power Down

3-20 Chapter 3: ASUS Remote Console3.2 ASUS Host Management Controller SetupThe ASUS Host Management Controller Setup utility provides precise congu

Pagina 51 - PET information

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-213.2.2 Command eldsThe utility menu bar has ve commands: Initial, View, Set, Monitor and Help. You can select a c

Pagina 52 - 6. Click OK

3-22 Chapter 3: ASUS Remote ConsoleTo view the System Data Record (SDR):1. Select BMC SDR from the View command option, then press <Enter>. A c

Pagina 53 - XP (Service Pack 2) users

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-23To view the BMC information:1. Select BMC Info from the View command option, then press <Enter>. A list of B

Pagina 54 - Controller Setup utility

3-24 Chapter 3: ASUS Remote Console3.2.5 SetThe Set command controls the host interface type and the correct BMC time.You can select from the followi

Pagina 55 - 3.2.3 Initial

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 3-253.2.6 MonitorThe Monitor command displays real-time data on the remote server system and CPU temperatures, voltage

Pagina 56

viNoticesFederal Communications Commission StatementThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two cond

Pagina 57 - To view the BMC information:

3-26 Chapter 3: ASUS Remote Console3.2.7 HelpThe Help command displays the available utility options, utility version, and copyright information.

Pagina 58 - 3.2.5 Set

4Web-based user interfaceThis chapter tells you how to use the web-based user interface that the server management board supports.

Pagina 59 - 3.2.6 Monitor

4-2 Chapter 4: Web-based user interface4.1 Web-based user interfaceThe web-based user interface allows you to easily monitor the remote server’s hard

Pagina 60 - 3.2.7 Help

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-34.1.2 Using the utilityThe web-based graphics user interface displays when you login in the utility successfully.1.

Pagina 61 - Web-based

4-4 Chapter 4: Web-based user interface4.2 System InformationThis section contains the general information about the system, such as rmware version

Pagina 62 - 4.1 Web-based user interface

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-54.3.1 Sensor Readings (with Thresholds)The Sensor Readings page displays the system sensor information, including r

Pagina 63 - 4.1.2 Using the utility

4-6 Chapter 4: Web-based user interface4.4 CongurationThis section allows you to congure the system settings. Click each function key to start usin

Pagina 64 - 4.3 Server Health

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-74.4.2 PEFThe PEF page allows you to modify the PEF conguration.11. Modify: Click to select the PEF item that you

Pagina 65 - 4.3.2 Event Log

4-8 Chapter 4: Web-based user interface4.4.4 NetworkThe Network page allows you to congure the network settings.1. MAC Address: Select whether to

Pagina 66 - 4.4 Conguration

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-94.4.6 SSLThe SSL page displays the default certicate and private key, and allows you to upload the new SSL certic

Pagina 67 - 4.4.3 Mouse Mode

viiREACHComplying with the REACH (Registration, Evaluation, Authorization, and Restriction of Chemicals) regulatory framework, we published the chemic

Pagina 68 - 4.4.5 SMTP

4-10 Chapter 4: Web-based user interface4.4.8 Congure LDAPThe Congure LDAP page allows you to authenticate and access the LDAP server. Complete the

Pagina 69 - 4.4.7 Users

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-114.5 Remote ControlThis section allows you to perform remote operations on the server. Click each function key to s

Pagina 70 - 4.4.9 Date/Time/NTP Settings

4-12 Chapter 4: Web-based user interface4.5.2 Server Power ControlThe Server Power Control page displays the current server power status and allows y

Pagina 71 - 4.5 Remote Control

ASUS ASMB4-iKVM/ASMB4-SOL PLUS 4-134.5.4 Chassis Identify CommandThe Chassis Identify Command page allows you to perform a chassis identify command c

Pagina 72 - 4.5.3 Capture Screen Video

4-14 Chapter 4: Web-based user interface4.7 LanguagesThis section allows you to select the language for the web-based application. Select the availab

Pagina 73 - 4.6 Maintenance

AAppendix: Reference informationThe Appendix shows the location of the LAN ports for server management and BMC connector on server motherboards. This

Pagina 74 - 4.7 Languages

A-2 Appendix: Reference informationA.1 BMC connectorThe ASUS server motherboards that support the ASMB4-iKVM/ASMB4-SOL PLUS comes with a Baseboard Ma

Pagina 75 - Appendix: Reference

ASUS ASMB4-iKVM/ASMB4-SOL PLUS A-3A.2 LAN ports for server managementThe ASUS server motherboards that support the ASMB4-iKVM/ASMB4-SOL PLUS comes wi

Pagina 76 - A.1 BMC connector

A-4 Appendix: Reference informationA.3 TroubleshootingProblem SolutionThe local/central server cannot connect to the ASMB4-iKVM/ASMB4-SOL PLUS board1

Pagina 77

ASUS ASMB4-iKVM/ASMB4-SOL PLUS A-5A.4 BMC Sensor Codes TableCategory 1: Memory relatedSensor No.Sensor Name Sensor Type Sensor Type codeSensor Value

Pagina 78 - A.3 Troubleshooting

viiiSafety informationElectrical safety• To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating t

Pagina 79 - A.4 BMC Sensor Codes Table

A-6 Appendix: Reference informationCategory 2: HDD / Backplane relatedSensor No. Sensor Name Sensor Type Sensor Type Code Sensor Value or Event Type0x

Pagina 80

ASUS ASMB4-iKVM/ASMB4-SOL PLUS A-7Category 3: Power Supply relatedSensor No. Sensor Name Sensor Type Sensor Type Code Sensor Value or Event Type0x81

Pagina 81

A-8 Appendix: Reference informationCategory 4: Hardware Monitor / System Sensor relatedSensor No. Sensor Name Sensor Type Sensor Type Code Sensor Valu

Pagina 82

ASUS ASMB4-iKVM/ASMB4-SOL PLUS A-90x3F P2VTT (For Intel DP platform only -- ASUS Z8 series server MB; -E6 server system) Voltage 0x02 Thresho

Pagina 83

A-10 Appendix: Reference information0xA2 FRNT_FAN1 FAN 0x04 Threshold(0x01) Lower Non-critical - going low Lower Critital - going low0xA3 FRNT_FA

Pagina 84

ixAbout this guideThis user guide contains the information you need when installing and conguring the server management board.How this guide is organ

Comentarios a estos manuales

Sin comentarios